中国机械工程 ›› 2013, Vol. 24 ›› Issue (07): 988-993.

• 学科发展 • 上一篇    下一篇

超声波测量接触刚度的研究进展

王世军;孙夏思;赵金娟;于雷   

  1. 西安理工大学,西安,710048
  • 出版日期:2013-04-10 发布日期:2013-04-27
  • 基金资助:
    国家重点基础研究发展计划(973计划)资助项目(2009CB724406);国家科技重大专项(2009ZX04014-032);西安理工大学科技创新计划资助项目(102-210916);西安理工大学博士启动基金资助项目(102-220411);陕西省教育厅科学研究计划资助项目(08JK393) 
    National Program on Key Basic Research Project (973 Program)(No. 2009CB724406);
    National Science and Technology Major Project ( No. 2009ZX04014-032);
    Shanxi Provincial Science Research Program of Ministry of Education of China(No. 08JK393)

Advances in Contact Stiffness Measurement Using Ultrasonic Method

Wang Shijun;Sun Xiasi;Zhao Jinjuan;Yu Lei   

  1. Xi'an University of Technology,Xi'an,710048
  • Online:2013-04-10 Published:2013-04-27
  • Supported by:
     
    National Program on Key Basic Research Project (973 Program)(No. 2009CB724406);
    National Science and Technology Major Project ( No. 2009ZX04014-032);
    Shanxi Provincial Science Research Program of Ministry of Education of China(No. 08JK393)

摘要:

介绍了超声波测量接触刚度的基本理论、实验方法和影响因素,对超声波测量接触刚度的研究历史和现状进行了分析和总结。超声波的波长远大于微凸体接触尺寸,接触表面的反射系数和入射系数是接触刚度的函数,根据实验获得的入射系数或者反射系数可以计算出接触刚度。超声波的频率、接触压力和材料的物理性质对接触刚度的测量有一定影响,接触压力较大时,纵波的反射系数和透射系数对载荷的变化不敏感,在这种情况下用横波检测比较好。利用超声波测量的接触刚度与理论计算出的刚度具有较好的一致性,表明超声波方法可以用于测量接触刚度并且具有一定可靠性。指出了超声波测量接触刚度研究中存在的问题和困难,展望了该技术在机械接触刚度测量方面的发展趋势。

关键词: 超声波, 结合部, 刚度, 粗糙表面, 接触

Abstract:

Theory, trial and influence factors of contact stiffness measurement using ultrasonic method were introduced, whose history and current situation were also analyzed and summarized. Because wavelength of ultrasonic wave is much longer than contact size of asperity, reflection coefficient and incidence coefficient of contact surface are function of contact stiffness. If the coefficients were obtained through trial, the contact stiffness can be calculated. Frequency of ultrasonic, contact pressure and physical property of material also have certain influence. When contact pressure is high, reflection coefficient and incidence coefficient of longitudinal wave are insensitive to variation of load. Under this condition, transverse wave is more suitable for contact stiffness measurement than longitudinal wave. The contact stiffness obtained by ultrasonic method accords well with theoretical result, it shows ultrasonic method may be used to measure contact stiffness and has certain reliability. Problems and difficulties are pointed out in research of
contact stiffness measurement using ultrasonic wave and its development tendency was forecasted.

Key words: utrasonic wave, joint, stiffness, rough surface, contact

中图分类号: